Skip to content
Wobistro

Refrigerated prep equipment

Refrigerated prep equipment keeps ingredient pans chilled where cooks assemble sandwiches, salads or pizzas.

Refrigerated prep equipment, Sandwich prep table, 3D model from the Wobistro kitchen catalogue
The default configuration as modelled in the Wobistro studio: a planning model, not a manufacturer photo.
FrontPlan 1.35 m 1.12 m 0.83 m
Planning envelope of the default configuration, 1.35 × 0.83 × 1.12 m. Not a manufacturer drawing.

Configurations and nominal sizes

ConfigurationSizeWidth × Depth × Height (m)Mounting
Countertop rail0.94 × 0.38 × 0.26On a counter or stand
1.22 × 0.38 × 0.26On a counter or stand
1.52 × 0.38 × 0.26On a counter or stand
Sandwich prep tableDoors: 21.35 × 0.83 × 1.12Floor
Doors: 31.98 × 0.83 × 1.12Floor
Pizza prep tableDoors: 21.49 × 0.95 × 1.16Floor
Doors: 32.15 × 0.95 × 1.16Floor

Nominal sizes describe a class of equipment, including handles and guards. They are planning envelopes, not manufacturer installation dimensions.

Options you can set

Select the placed piece in the studio to change these. Size-driving options resize the piece.

Countertop rail

Ingredient pans
5, 4, 6, or 8

Sandwich prep table

Doors
2 or 3
Hinge side
Left or Right

Pizza prep table

Doors
2 or 3
Hinge side
Left or Right

Pan capacity

Countertop rail: As configured by default, the pan opening holds 5 × GN 1/6 pans. You can change pan sizes, depths and contents in the studio.

Sandwich prep table: As configured by default, the pan opening holds 6 × GN 1/6 pans. You can change pan sizes, depths and contents in the studio.

Pizza prep table: As configured by default, the pan opening holds 7 × GN 1/6 pans. You can change pan sizes, depths and contents in the studio.

Planning checks

Facing work stations are checked for an aisle of at least 1.05 m between their fronts. This is a Wobistro planning target.

Each work station is checked for a clear walking route of 3 m or less to a handwashing sink. This is a Wobistro planning target.

FDA Food Code, sections 5-204.11 and 5-205.11

The kitchen space programme allows 0.9 m of working space in front of it (planning estimate).

These are planning checks, not approval. Confirm hood, fire, gas and health requirements with the code adopted where the kitchen is.

Connections

Typical connection: electric.

Connection types are planning information. Confirm loads, gas ratings and drainage with the selected model and your engineer.

In the operations simulator

When you simulate the layout you drew, this equipment loads the Cold prep station.

ConfigurationPlanning capacityBasis
Countertop rail60 portions/hPlanning estimate
Sandwich prep table60 portions/hPlanning estimate
Pizza prep table60 portions/hPlanning estimate

Simulator figures are planning starting points. Time your own menu on your own equipment.

In example venues

This equipment is placed in these example venues, which you can open in 3D.

Plan it in your kitchen

Opens the studio with this equipment placed and selected in the venue you last worked on, or in a new room if you have none. You can try it without an account.

Place it in the studio

Or open “Corner burger restaurant with open kitchen”, an example venue that uses it.