How Wobistro’s simulator computes its numbers
The method, formulas and defaults behind every covers, equipment, staffing and space figure on Wobistro, in the guides, the calculators and the studio.
Short answer
Wobistro sizes a venue the way foodservice consultants do: covers from seats and turnover, the busiest quarter-hour from an hourly demand curve, portions per hour from the menu mix, then equipment and people as peak load divided by what one unit or one person can sustain, rounded up. A discrete-event simulation then runs 200 varied days to measure ticket times, queues and lost sales. Every default carries a basis label: sourced, recalled or estimated.
What the labels mean
- Sourced: read from a manufacturer spec sheet, a dealer guide, a trade publication or a code body; the label links to the page.
- Recalled: a published code or industry rule entered from the text of the code. Confirm it against the edition adopted where you build; our guides cite the primary page.
- Estimated: a working default with no published source. It is a starting point to replace with your own figure.
- Yours: anything you set in the studio overrides the default and is labelled as yours in the results.
1. Demand: covers per day and the busiest quarter-hour
Dine-in covers per day = seats × covers per seat per day. Off-premises orders are added on top: total covers = dine-in covers ÷ (1 − off-premises share). The plan is sized for a busy day, 1.2 × the average day, not the average.
The day is spread over the open hours with a lunch peak and a dinner peak, weighted by the concept’s lunch share and scaled so the busiest hour carries the concept’s busiest-hour share. The busiest quarter-hour runs at 1.25 × the average rate of the busiest hour; equipment and people are sized for that quarter-hour.
| Concept | Service | Covers per seat per day | Minutes at the table | Off-premises share | Busiest-hour share | Average check | Dining area per seat |
|---|---|---|---|---|---|---|---|
| Fast casual | counter | 5 | 30 | 35% | 15% | $15 | 18 sq ft (sourced) |
| Quick service | counter | 9 | 15 | 60% | 15% | $10 | 13 sq ft (sourced) |
| Casual dining | table | 2.5 | 60 | 20% | 18% | $28 | 13 sq ft (sourced) |
| Fine dining | table | 1.2 | 120 | 3% | 20% | $110 | 19 sq ft (sourced) |
| Café | counter | 5 | 35 | 45% | 18% | $8 | 16 sq ft (estimated) |
| Bar | table | 2 | 75 | 0% | 22% | $24 | 12 sq ft (estimated) |
| Pizzeria | table | 3 | 55 | 40% | 20% | $18 | 14 sq ft (estimated) |
| Delivery kitchen | counter | 0 | 0 | 100% | 18% | $16 | — |
2. Equipment: peak load ÷ dependable capacity
Each menu item is made by one process, and each process loads one piece of equipment. Units required = peak quarter-hour load ÷ (rated capacity per unit × the share of that rating you can count on), rounded up. The dependable share defaults to 70%. Griddles, charbroilers and bar counters grow with width rather than count, in standard modules of 0.6, 0.9, 1.2, 1.5, 1.8, 2.4 m, the metric equivalents of the 24 to 96 in modules equipment is sold in.
| Process | Equipment | Capacity | Per | Basis |
|---|---|---|---|---|
| Griddled patty | griddle | 190 (130–260) patties/h | metre of width | estimated |
| Griddled item | griddle | 190 (130–260) pieces/h | metre of width | estimated |
| Chargrilled item | charbroiler | 100 (65–130) pieces/h | metre of width | estimated |
| Fried side | fryer | 31.8 (27–36.3) kg/h | unit | sourced |
| Fried main | fryer | 31.8 (27–36.3) kg/h | unit | sourced |
| Pan dish | six-burner range | 72 (48–90) dishes/h | unit | estimated |
| Oven dish | combi oven | 60 (30–100) portions/h | unit | estimated |
| Baked item | convection oven | 120 (80–160) portions/h | unit | estimated |
| Deck-oven pizza | pizza deck oven | 20 (15–25) pizzas/h | unit | estimated |
| Conveyor-oven pizza | pizza conveyor oven | 57 (44–67) pizzas/h | unit | sourced |
| Cold dish | refrigerated prep rail | 60 (40–80) portions/h | unit | estimated |
| Espresso drink | espresso machine | 110 (80–120) drinks/h | unit | estimated |
| Fountain or bottled drink | beverage dispenser | 160 (120–200) drinks/h | unit | estimated |
| Bar drink | bar counter | 27 (17–37) drinks/h | metre of width | estimated |
| Draft beer | beer taps | 240 (160–320) drinks/h | unit | estimated |
The exhaust hood spans every hooded appliance plus 0.3 m (about 1 ft), rounded up to the next 0.3 m. Exhaust = hood length in feet × 250 cfm per foot for medium duty (sourced), × 0.7 for light-duty lines and × 1.4 where a charbroiler makes the line heavy duty. Your mechanical engineer sizes the real hood under the mechanical code adopted locally.
The California Energy Commission design guide linked as the source of the 250 cfm per foot default could not be opened on November 22, 2026. For comparison, an ICC training handout on an earlier International Mechanical Code edition lists 300 cfm per foot as the minimum for a medium-duty wall-mounted canopy, and California’s energy code, Title 24 Part 6 Table 140.9-A, caps the same hood at 210 cfm per foot in kitchens whose total hood exhaust exceeds 5,000 cfm, a limit set for UL-listed hoods. The real rate comes from the listing of the hood you buy and from your engineer.
3. Staffing: people per station
People per station = peak quarter-hour load ÷ (sustainable rate per person × 85%, the share of full pace a team holds through a rush), rounded up, with at least one person wherever there is work. The crew is reported as a range: one person per station is the ceiling; a cross-trained team covering quiet stations is the floor.
| Station | Sustainable rate per person | Unit per hour | Basis |
|---|---|---|---|
| Order point | 50 (40–60) | orders | estimated |
| Grill | 120 (80–160) | pieces | estimated |
| Fry | 100 (60–150) | portions | estimated |
| Sauté | 30 (20–40) | dishes | estimated |
| Oven | 60 (40–90) | portions | estimated |
| Pizza | 35 (20–50) | pizzas | estimated |
| Cold prep | 60 (40–80) | portions | estimated |
| Assembly | 80 (50–100) | mains | estimated |
| Coffee bar | 50 (40–60) | drinks | estimated |
| Bar | 40 (25–55) | drinks | estimated |
| Expo and drinks | 60 (40–80) | tickets | estimated |
| Floor service | 12 (10–14) | covers | estimated |
| Dish | 32 (25–40) | racks | estimated |
4. The simulated service
The sizing above answers “how much”. The simulation answers “how long”: parties arrive at random through the day following the demand curve, order, wait for each piece of equipment and each station, and sit for a randomly varied time. Each of the 200 runs is a different day with its own demand level (day-to-day variation 15%) and task-time variation (50%). Parties walk away when the queue reaches 10 parties or after 15 minutes waiting for a table. Results report the median, the 95th percentile and a bad day (the 95th percentile across days).
Published examples in our guides use a fixed random seed (1) so the same inputs always print the same figures; the studio lets you change it.
5. Space and code checks
Dining area = seats × the concept’s area per seat. Total floor area = dining area ÷ (1 − kitchen and back-of-house share). These are planning allowances, not a layout.
The simulator then raises checks to take to the building department, never as approval: occupant load of the dining room at 15 sq ft net per person for tables and chairs (sourced), toilets at one water closet per 75 occupants of each sex (recalled), accessible seating at 5% of seats (recalled) and a 36 in (92 cm) accessible route (recalled). Our guides cite the primary text for each.
The Minnesota page cited in the simulator data no longer resolves (404 on 2026-11-22). The 15 sq ft net figure was checked against Table 1004.5 as adopted in Washington’s building code: WAC 51-50-1004, Table 1004.5.
6. A first look at the money
Labour hours = the average of the two crew figures × open hours × 0.7 for lighter crews outside the peaks (estimated); labour cost uses $21 an hour loaded (estimated). Food cost defaults to 30% of sales (estimated). Revenue is covers × average check on an average day. Treat these as a sanity check, not a forecast.
Every default the simulator uses
| Assumption | Default (range) | Unit | Basis |
|---|---|---|---|
| Busy-day uplift | 1.2 (1.1–1.5) | × | estimated |
| Busiest quarter-hour vs the peak hour | 1.25 (1.1–1.5) | × | estimated |
| Share of rated output you can count on | 70% (65%–75%) | share | sourced |
| Share of full pace staff can hold through a rush | 85% (70%–95%) | share | estimated |
| Covers per takeaway or delivery order | 1.5 (1.3–3) | covers | estimated |
| Takeaway orders placed online | 60% (30%–90%) | share | estimated |
| Queue length at which people walk away | 10 (6–16) | parties | estimated |
| Minutes a party waits for a table | 15 (8–30) | min | estimated |
| Variability of task times | 0.5 (0.3–0.8) | cv | estimated |
| Day-to-day swing in demand | 0.15 (0.08–0.25) | cv | estimated |
| Dish racks per dine-in meal | 0.35 (0.3–0.4) | racks | sourced |
| Ice per cover | 0.68 (0.68–0.9) | kg | sourced |
| Chilled stock per cover | 0.41 (0.3–0.55) | kg | estimated |
| Days of chilled stock held | 3.5 (2–5) | days | estimated |
| Hood exhaust per foot, medium duty | 250 (200–300) | cfm/ft | sourced |
| Loaded labour cost per hour | $21 ($14–$30) | USD | estimated |
| Food cost share of sales | 30% (25%–38%) | share | estimated |
What this method does not do
- It does not measure your market: covers come from your seats and stated turnover, not from foot traffic or demand data.
- It does not replace an engineer, an architect or a plan reviewer. Hoods, fire suppression, plumbing fixtures, egress and accessibility are decided under the codes adopted where you build.
- Estimated defaults are not benchmarks. Time your own line and replace them.
Where to see it run: planning numbers by concept, the calculators and the studio. Questions or corrections: contact us.