Skip to content
Wobistro

How Wobistro’s simulator computes its numbers

The method, formulas and defaults behind every covers, equipment, staffing and space figure on Wobistro, in the guides, the calculators and the studio.

Short answer

Wobistro sizes a venue the way foodservice consultants do: covers from seats and turnover, the busiest quarter-hour from an hourly demand curve, portions per hour from the menu mix, then equipment and people as peak load divided by what one unit or one person can sustain, rounded up. A discrete-event simulation then runs 200 varied days to measure ticket times, queues and lost sales. Every default carries a basis label: sourced, recalled or estimated.

What the labels mean

1. Demand: covers per day and the busiest quarter-hour

Dine-in covers per day = seats × covers per seat per day. Off-premises orders are added on top: total covers = dine-in covers ÷ (1 − off-premises share). The plan is sized for a busy day, 1.2 × the average day, not the average.

The day is spread over the open hours with a lunch peak and a dinner peak, weighted by the concept’s lunch share and scaled so the busiest hour carries the concept’s busiest-hour share. The busiest quarter-hour runs at 1.25 × the average rate of the busiest hour; equipment and people are sized for that quarter-hour.

ConceptServiceCovers per seat per dayMinutes at the tableOff-premises shareBusiest-hour shareAverage checkDining area per seat
Fast casualcounter53035%15%$1518 sq ft (sourced)
Quick servicecounter91560%15%$1013 sq ft (sourced)
Casual diningtable2.56020%18%$2813 sq ft (sourced)
Fine diningtable1.21203%20%$11019 sq ft (sourced)
Cafécounter53545%18%$816 sq ft (estimated)
Bartable2750%22%$2412 sq ft (estimated)
Pizzeriatable35540%20%$1814 sq ft (estimated)
Delivery kitchencounter00100%18%$16—

2. Equipment: peak load ÷ dependable capacity

Each menu item is made by one process, and each process loads one piece of equipment. Units required = peak quarter-hour load ÷ (rated capacity per unit × the share of that rating you can count on), rounded up. The dependable share defaults to 70%. Griddles, charbroilers and bar counters grow with width rather than count, in standard modules of 0.6, 0.9, 1.2, 1.5, 1.8, 2.4 m, the metric equivalents of the 24 to 96 in modules equipment is sold in.

ProcessEquipmentCapacityPerBasis
Griddled pattygriddle190 (130–260) patties/hmetre of widthestimated
Griddled itemgriddle190 (130–260) pieces/hmetre of widthestimated
Chargrilled itemcharbroiler100 (65–130) pieces/hmetre of widthestimated
Fried sidefryer31.8 (27–36.3) kg/hunitsourced
Fried mainfryer31.8 (27–36.3) kg/hunitsourced
Pan dishsix-burner range72 (48–90) dishes/hunitestimated
Oven dishcombi oven60 (30–100) portions/hunitestimated
Baked itemconvection oven120 (80–160) portions/hunitestimated
Deck-oven pizzapizza deck oven20 (15–25) pizzas/hunitestimated
Conveyor-oven pizzapizza conveyor oven57 (44–67) pizzas/hunitsourced
Cold dishrefrigerated prep rail60 (40–80) portions/hunitestimated
Espresso drinkespresso machine110 (80–120) drinks/hunitestimated
Fountain or bottled drinkbeverage dispenser160 (120–200) drinks/hunitestimated
Bar drinkbar counter27 (17–37) drinks/hmetre of widthestimated
Draft beerbeer taps240 (160–320) drinks/hunitestimated

The exhaust hood spans every hooded appliance plus 0.3 m (about 1 ft), rounded up to the next 0.3 m. Exhaust = hood length in feet × 250 cfm per foot for medium duty (sourced), × 0.7 for light-duty lines and × 1.4 where a charbroiler makes the line heavy duty. Your mechanical engineer sizes the real hood under the mechanical code adopted locally.

The California Energy Commission design guide linked as the source of the 250 cfm per foot default could not be opened on November 22, 2026. For comparison, an ICC training handout on an earlier International Mechanical Code edition lists 300 cfm per foot as the minimum for a medium-duty wall-mounted canopy, and California’s energy code, Title 24 Part 6 Table 140.9-A, caps the same hood at 210 cfm per foot in kitchens whose total hood exhaust exceeds 5,000 cfm, a limit set for UL-listed hoods. The real rate comes from the listing of the hood you buy and from your engineer.

3. Staffing: people per station

People per station = peak quarter-hour load ÷ (sustainable rate per person × 85%, the share of full pace a team holds through a rush), rounded up, with at least one person wherever there is work. The crew is reported as a range: one person per station is the ceiling; a cross-trained team covering quiet stations is the floor.

StationSustainable rate per personUnit per hourBasis
Order point50 (40–60)ordersestimated
Grill120 (80–160)piecesestimated
Fry100 (60–150)portionsestimated
Sauté30 (20–40)dishesestimated
Oven60 (40–90)portionsestimated
Pizza35 (20–50)pizzasestimated
Cold prep60 (40–80)portionsestimated
Assembly80 (50–100)mainsestimated
Coffee bar50 (40–60)drinksestimated
Bar40 (25–55)drinksestimated
Expo and drinks60 (40–80)ticketsestimated
Floor service12 (10–14)coversestimated
Dish32 (25–40)racksestimated

4. The simulated service

The sizing above answers “how much”. The simulation answers “how long”: parties arrive at random through the day following the demand curve, order, wait for each piece of equipment and each station, and sit for a randomly varied time. Each of the 200 runs is a different day with its own demand level (day-to-day variation 15%) and task-time variation (50%). Parties walk away when the queue reaches 10 parties or after 15 minutes waiting for a table. Results report the median, the 95th percentile and a bad day (the 95th percentile across days).

Published examples in our guides use a fixed random seed (1) so the same inputs always print the same figures; the studio lets you change it.

5. Space and code checks

Dining area = seats × the concept’s area per seat. Total floor area = dining area ÷ (1 − kitchen and back-of-house share). These are planning allowances, not a layout.

The simulator then raises checks to take to the building department, never as approval: occupant load of the dining room at 15 sq ft net per person for tables and chairs (sourced), toilets at one water closet per 75 occupants of each sex (recalled), accessible seating at 5% of seats (recalled) and a 36 in (92 cm) accessible route (recalled). Our guides cite the primary text for each.

The Minnesota page cited in the simulator data no longer resolves (404 on 2026-11-22). The 15 sq ft net figure was checked against Table 1004.5 as adopted in Washington’s building code: WAC 51-50-1004, Table 1004.5.

6. A first look at the money

Labour hours = the average of the two crew figures × open hours × 0.7 for lighter crews outside the peaks (estimated); labour cost uses $21 an hour loaded (estimated). Food cost defaults to 30% of sales (estimated). Revenue is covers × average check on an average day. Treat these as a sanity check, not a forecast.

Every default the simulator uses

AssumptionDefault (range)UnitBasis
Busy-day uplift1.2 (1.1–1.5)×estimated
Busiest quarter-hour vs the peak hour1.25 (1.1–1.5)×estimated
Share of rated output you can count on70% (65%–75%)sharesourced
Share of full pace staff can hold through a rush85% (70%–95%)shareestimated
Covers per takeaway or delivery order1.5 (1.3–3)coversestimated
Takeaway orders placed online60% (30%–90%)shareestimated
Queue length at which people walk away10 (6–16)partiesestimated
Minutes a party waits for a table15 (8–30)minestimated
Variability of task times0.5 (0.3–0.8)cvestimated
Day-to-day swing in demand0.15 (0.08–0.25)cvestimated
Dish racks per dine-in meal0.35 (0.3–0.4)rackssourced
Ice per cover0.68 (0.68–0.9)kgsourced
Chilled stock per cover0.41 (0.3–0.55)kgestimated
Days of chilled stock held3.5 (2–5)daysestimated
Hood exhaust per foot, medium duty250 (200–300)cfm/ftsourced
Loaded labour cost per hour$21 ($14–$30)USDestimated
Food cost share of sales30% (25%–38%)shareestimated

What this method does not do