Grease trap requirements for restaurants: types, sizing and cleaning
Grease trap vs grease interceptor, what drains to it, how cities size it from drainage fixture units, how often to clean it and where it goes in the plan.
Short answer
Most US cities require a restaurant to run its grease-bearing drains, such as the pot sink, mop sink, floor drains and dish machine, through a grease trap (hydromechanical, indoors) or a grease interceptor (gravity, usually buried outside). Small kitchens with few fixtures may use a trap; larger ones, or any with a dish machine or garbage disposal, are often required to install a gravity interceptor of at least 500 gallons. Size comes from drainage fixture units, and cleaning is due before fats and solids fill about a quarter of the unit.

Grease trap or grease interceptor: two devices, one job
Fats, oils and grease (FOG) cool in the sewer, harden and block it, so cities make restaurants catch them first. The device has two common forms, and the names are used loosely. Phoenix’s manual, written for food service operators, separates them [1]:
- Hydromechanical interceptors, “also commonly known as grease traps”, are usually small and installed indoors. Phoenix approves them for establishments with up to four plumbing fixtures, typically a three-compartment sink, prep sink and mop sink, and says no garbage disposal or dishwasher may discharge to one [1].
- Gravity grease interceptors are much larger tanks installed outdoors. Phoenix requires them for establishments with more than four plumbing fixtures, and for any with a garbage disposal or a dishwasher regardless of the number of fixtures [1].
Other cities draw the line elsewhere. Tukwila, Washington, says its hydromechanical units can be located inside or outside, need a vented flow restrictor, and are limited by a rule that the total capacity of the fixtures draining to one, in gallons, may not exceed two and a half times its certified flow rate in gallons per minute; its gravity interceptors are generally in the ground outside and at least 500 gallons [2]. Austin says hydromechanical units are generally suited to low-FOG establishments, while a food preparation facility with a dishwasher must install a gravity interceptor of at least 500 gallons [3].
The code underneath is the same idea. New York City’s 2022 Plumbing Code requires a grease interceptor or an automatic grease removal device to receive the drainage from fixtures and equipment with waste containing fats, oils or grease in food preparation areas, and says it must receive waste only from fixtures that allow FOG to be discharged [4]. It also says wastes that do not need treatment must not be discharged into an interceptor [4].
What drains to it, and what does not
Phoenix lists the “grease bearing fixtures” it counts: floor sinks, floor drains, mop sinks, trough sinks, trough drains, pre-wash sinks, prep sinks, pot sinks, can wash sinks, dishwashers and garbage disposals in the kitchen prep or wash area. Hand wash sinks do not apply, and condensate or cooler drain lines are not to be routed to the line that feeds the interceptor [1]. Tukwila agrees on the edges: produce prep sinks and hand washing sinks do not need to connect, floor sinks that receive only ice machine and cooler condensate are not counted, and a new mop sink must be connected if meat is cooked [2].
Two fixtures cause most of the argument. Dish machines are the first: Phoenix will not let one drain to a hydromechanical unit, and Austin requires a gravity interceptor of at least 500 gallons where there is one [1] [3]. Garbage disposals add solids: Phoenix lengthens the sizing retention time when one is present, and Tukwila says FOG-bearing food waste disposers can only discharge to a properly sized gravity interceptor [1] [2]. If you can leave the disposer out of the plan, do. See the commercial dishwasher guide for the machine itself and the commercial kitchen sink guide for which sinks the kitchen needs in the first place.
How cities size the device
Sizing starts from the same unit, the drainage fixture unit (DFU), a plumbing-code measure of the load a fixture puts on the drain. Tukwila’s guide lists values drawn from the 2021 Uniform Plumbing Code: a three-compartment sink is 9 DFUs, a mop sink 3, a floor drain 2, and a dishwasher is counted like a floor sink of its drain size, so a dishwasher with a 2-inch drain to a floor sink is 4 [2]. From the DFU total, three methods are common.
| City | Method | Stated limits |
|---|---|---|
| Phoenix, gravity | DFUs × 3 gallons a minute × 12-minute retention (17 minutes with a garbage disposal) | Minimum 500 gallons; two compartments |
| Austin | Flow rating = fixture units × 3 gal/min; capacity = flow rating × 12 minutes | Hydromechanical at least 75 gpm; with a dishwasher at least 500 gallons; no trap under 100 gallons |
| Tukwila | Read the interceptor from a table by total DFUs | 500 gallons up to 8 DFUs, 750 up to 21, 1,000 up to 35 (gravity) |
Sources: [1] [3] [2]. Austin adds that for dishwashers and compartment sinks that drain indirectly through a floor sink or hub drain, the fixture unit count is doubled, and that dishwasher fixture units are 6 for a 3-inch trap and 8 for a 4-inch trap [3], so check how your city counts before you tally.
Small hydromechanical traps are sized differently, by the flow they can pass and the grease they can hold. The Uniform Plumbing Code table reproduced in Phoenix’s worksheet [1]:
| Fixtures connected | Required flow rate (gal/min) | Grease retention (lb) |
|---|---|---|
| 1 | 20 | 40 |
| 2 | 25 | 50 |
| 3 | 35 | 70 |
| 4 | 50 | 100 |
Tukwila’s version of the hydromechanical table runs by DFU instead, from a 20 gpm unit at up to 8 DFUs to a 75 gpm unit at up to 35 [2]. Phoenix also requires hydromechanical units to be corrosion resistant, and certified by the Plumbing and Drainage Institute (PDI) or listed to the UPC [1]; New York City refers to PDI G101, ASME A112.14.3 or ASME A112.14.4 [4]. Ask for the listing before you buy.
Tukwila also has a quick screen for the type. A hydromechanical unit is allowed only if the restaurant has 40 seats or fewer, serves fewer than 40 meals an hour and has no food grinder; otherwise a gravity interceptor is required. Meals per peak hour is seats times a factor: 1.33 for fast food, 1.00 for a restaurant, 0.67 for leisure dining and 0.50 for a dinner club [2].
Worked example: an 80-seat kitchen
The simulator in Wobistro proposes the equipment for a venue from its seats and menu. For 80-seat venues it proposes these grease-bearing fixtures:
| Concept | Three-compartment sinks | Dish machines | Grease-bearing equipment proposed |
|---|---|---|---|
| Fast casual | 1 | 1 | 2 |
| Casual dining | 1 | 1 | 2 |
| Café | 1 | 1 | 2 |
| Bar | 1 | 1 | 2 |
The simulator does not draw the mop sink, floor drains or floor sinks, which come from the architect’s plumbing plan, and its hand sinks are not counted for the reason above. To see what a real tally looks like, add a mop sink and two floor drains to one three-compartment sink and one dish machine with a 2-inch drain to a floor sink, using Tukwila’s values: 9 + 3 + 4 + 2 × 2 = 20 DFUs [2]. This is an illustration of the arithmetic, not a design.
| Method | Result for 20 DFUs |
|---|---|
| Phoenix formula, no garbage disposal | 20 × 3 × 12 = 720 gallons |
| Austin formula | 20 × 3 = 60 gpm flow rating, × 12 min = 720 gallons |
| Tukwila gravity table | Above 8 DFUs and up to 21: a 750-gallon unit |
The three agree to within a standard tank size, which is the useful point: a sit-down kitchen with a dish machine lands in the several-hundred-gallon range, not in the small indoor trap range. The seat count matters too. Tukwila’s screen for 80 seats serving a restaurant at a factor of 1.00 gives 80 meals an hour, above the 40-meal limit for a hydromechanical unit, and a fast-casual kitchen at 1.33 gives about 106 [2]. An interceptor that size is a buried concrete or plastic tank, and it is a construction item, not an equipment line.
Cleaning, pumping and records
Interceptors stop working when they fill. Phoenix says most types stop working effectively when fats, oils and solids reach 25 percent of the device’s capacity, and if they exceed that the operator must have it fully cleaned by a licensed pumper, leaving it completely empty [1]. Its minimum schedules: hydromechanical units fully pumped and cleaned every 30 days, and never more than 90 days without maintenance; gravity interceptors at least every 3 months, unless the city grants a variance [1]. Chemicals, enzymes, bacteria and emulsifiers used to dissolve grease for a while are prohibited [1]. Tukwila’s rule combines the two: clean when FOG or solids reach 25 percent of any chamber, or at least every three months, whichever comes first [2].
New York City’s code is shorter: access must be provided to every interceptor for service, maintenance and inspection, and interceptors are maintained by periodic removal of accumulated grease, scum, oil and solids [4]. Phoenix requires the operator to keep maintenance records, including pumper invoices, on site for three years, and its inspectors check the records, the interceptor itself and the number of grease-bearing fixtures [1]. Tukwila’s guide shows sample permanent signage and a sample maintenance log [2]. Lease holders should note that in a multi-tenant building the owner may carry the responsibility for a shared interceptor; Phoenix assigns it to the property owner in that case [1].
Permits, plan review and where it goes in the plan
Phoenix runs grease interceptor installation and replacement through plan review, to check the size, that the device is on the approved list and that every grease-bearing fixture is plumbed to it. The plans show every such fixture, the manufacturer and model, and an orientation mark [1]. Expect a plumbing floor plan and, if any fixture is rerouted or added, an isometric drawing showing pipe size and venting [1]. This sits beside the health department’s review described in our plan review guide.
For placement, three published rules shape the plan:
- Phoenix requires interceptors to be free from obstructions and readily accessible for cleaning and inspection [1], and New York requires access for service and for inspection by the city [4]. A pumper truck needs a route to the lid.
- The discharge piping of an interceptor connects directly to the sanitary drain [4], so the tank sits on the way out of the kitchen, between the grease-bearing drains and the sewer connection.
- In existing buildings space for a gravity interceptor may not exist; Tukwila’s guide suggests splitting the fixtures into smaller groups, each through an appropriately sized hydromechanical unit [2].
Put the dish area, the pot sink and the mop sink on the wall nearest the point where the drain leaves the building, and keep the floor drains of the cook line on the same run. The kitchen plans by concept show where the dirty flow ends in each kitchen type, and the equipment catalogue lists the utilities for the compartment sink and the commercial dishwasher. Drag them around in the studio to see how far the dirty side is from the back wall.
Grease interceptor checklist
- Ask the sewer or wastewater utility which device it requires and whether a dish machine or disposer changes the answer.
- List every grease-bearing fixture: pot and prep sinks, mop sink, floor drains and floor sinks, dish machine. Leave out hand sinks and ice or cooler condensate unless your city says otherwise.
- Count drainage fixture units with your city’s table and size the device with its formula or chart.
- Reserve outdoor or under-slab space and truck access for a gravity interceptor before you fix the layout.
- Specify a certified device (PDI, ASME or UPC listing) and show manufacturer and model on the plans.
- Set a cleaning schedule from the start: before 25 percent full, and not less than the city’s minimum interval.
- Keep pumper invoices and the log on site for the period your city requires.
Work it out for your venue
- Commercial kitchen equipment catalogue
Sizes, utilities and simulator capacity for each equipment family Wobistro can place in a plan.
- Open the Wobistro studio
Start from photos, a floor plan or an example venue and edit it in 3D, with the simulator built in.
- Kitchen plans by concept
Zone programmes, clean and dirty flows and equipment by kitchen type, from 100 to 600 covers.
Questions
What is the difference between a grease trap and a grease interceptor?
A grease trap, called a hydromechanical interceptor in Phoenix’s manual, is a small unit usually installed indoors and used where only a few fixtures drain to it. A gravity grease interceptor is much larger, usually installed outdoors, and is required for larger kitchens or any with a dish machine or garbage disposal in Phoenix.
Does a dishwasher have to drain to a grease interceptor?
In Phoenix a dishwasher may not drain to a hydromechanical unit and requires a gravity interceptor, and Austin requires a gravity interceptor of at least 500 gallons for a facility with a dishwasher. Tukwila instead counts a dishwasher’s drain in its fixture unit total. Your local utility decides.
How do you size a grease interceptor?
Most cities add up the drainage fixture units of every fixture that drains to it. Phoenix and Austin multiply that total by 3 gallons per minute and a 12-minute retention time, and Phoenix uses 17 minutes with a garbage disposal. Tukwila reads the size from a table. For 20 fixture units the formula gives 720 gallons.
How often does a grease trap need to be cleaned?
Before fats, oils and solids reach about a quarter of its capacity, and on a fixed schedule as well in some cities. Phoenix requires full cleaning above 25 percent and sets minimum intervals, and Tukwila says clean at 25 percent of any chamber or at least every three months. Records must be kept on site.
Do hand sinks drain to the grease trap?
Usually not. Tukwila says hand washing sinks and produce prep sinks do not need to connect to the grease device, and Phoenix says hand wash sinks do not count as grease-bearing fixtures. Pot sinks, mop sinks, floor drains and dish machines generally do.
Sources
- City of Phoenix Water Services Department, Fats, Oils and Greases (FOG) Best Management Practices for Food Service Establishments (June 2024), Types of interceptors; maintenance; sizing; plan review checklist; fixture count worksheet with UPC Table 10-2. Accessed November 22, 2026.
- City of Tukwila, Washington, Permit Center, Grease Interceptor/Trap Sizing Installation Guide (revised April 2025), Definitions; Tables 1, 4 and 5; meals-per-hour formula; decision tree. Accessed November 22, 2026.
- City of Austin, Grease trap sizing design criteria, Sizing steps; hydromechanical and gravity requirements; dishwashers. Accessed November 22, 2026.
- NYC Department of Buildings, 2022 NYC Plumbing Code, Chapter 10: Traps, Interceptors and Separators, §1003.2, §1003.3.1, §1003.3.4, §1003.3.6, §1003.10. Accessed November 22, 2026.
Figures marked as Wobistro estimates come from the simulator defaults described in our methodology. Found an error? Tell us and we will correct it under our editorial standards.